Air Line arrow ETL3000
ETL3000
ETL3000 Download brochure (0,71 MB)

MULTI-COMPONENT OUTDOOR AIR QUALITY MONITOR

• ETL3000 PROVIDES HIGH QUALITY DATA AT AN AFFORDABLE PRICE

• USING CO, NO2, O3 THICK FILM SENSORS Optional C6H6 and other sensors (see the list)

• BUILT-IN NOISE METER (Leq), AIR TEMPERATURE AND RELATIVE HUMIDITY SENSORS

• BUILT-IN DATA LOGGER (Flash memory)

• 15’ MINUTES OR HOURLY AVERAGES

• GSM MODEM FOR REMOTE DATA HANDLING

• OUTDOOR INSTALLATION

• LITTLE MAINTENANCE

APPLICATIONS

• URBAN TRAFFIC POLLUTION SCREENING MONITORING

• ROADSIDE MONITORING

• INTEGRATION WITH TRAFFIC CONTROL SYSTEMS

• INTEGRATION WITH TRADITIONAL AIR QUALITY NETWORKS

• AIR QUALITY MONITORING FOR INDUSTRIAL AREAS

• BOUNDARY MONITORING OF LANDFILL SITES (WITH OPTIONAL MEASUREMENT OF CH4, H2S AND NH3).

• OPTIONAL: BUILT –IN PM10 MONITOR

General Features

The ETL3000 is a multi-component air quality monitor for measuring airborne pollutants in parts per billion (ppb) concentrations. The system is based on a new solid-state thick-film sensor technology, which provides excellent sensitivity and accuracy. The performance of the sensors is superior to conventional electrochemical cells. The monitor provides measurement of CO, NO2 and O3. In addition temperature, humidity and noise is simultaneously measured. The system has a built-in data logger and a GSM modem (optional). Analysis of C6H6 and other parameters with thick film sensor is also available as option.

The ETL3000 is designed specifically for outdoor installation. A mounting kit is supplied, suitable for any pole diameter. The electonic part is now based on a microprocessor with flash memory and it is completely separated by the sensors. Each sensor is indipendent and is installed inside its cell (SENS3000) and connected to the electonic with plug-play connectors. The sensors can be replaced easily in the field.

Our innovative application of Mobile Monitoring of Traffic Pollution in cities can be done by installing the ETLBUS system on public transport vehicles and positioning using GPS.

It is possible to develop special custom applications of ETLBUS and software with GIS system to handle also instantaneous data positioned on the local map.

Unitec Srl - Via C. Colombo, 37/E CAP 44100 Ferrara Italy Tel +39 0532 731123 - Fax +39 0532 730537 - P. Iva 01497740389 - Privacy
Cap. Soc. Euro 200.000,00 - interamente versato - Reg. Imprese Ferrara n. 01497740389 - R.E.A Ferrara n. 173048